JLinkLog.txt 4.7 KB

12345678910111213141516171819202122232425262728293031323334353637383940414243444546474849505152535455565758596061626364656667686970717273747576777879808182838485868788899091
  1. T24CC 000:007.431 SEGGER J-Link V7.96j Log File
  2. T24CC 000:007.907 DLL Compiled: May 29 2024 15:36:36
  3. T24CC 000:007.912 Logging started @ 2024-08-03 02:51
  4. T24CC 000:007.916 Process: C:\Keil_v5\UV4\UV4.exe
  5. T24CC 000:008.090 - 7.920ms
  6. T24CC 000:008.277 JLINK_SetWarnOutHandler(...)
  7. T24CC 000:008.282 - 0.179ms
  8. T24CC 000:008.288 JLINK_OpenEx(...)
  9. T24CC 000:011.663 Firmware: J-Link V9 compiled May 7 2021 16:26:12
  10. T24CC 000:012.397 Firmware: J-Link V9 compiled May 7 2021 16:26:12
  11. T24CC 000:012.925 Decompressing FW timestamp took 360 us
  12. T24CC 000:018.511 Hardware: V9.50
  13. T24CC 000:018.523 S/N: 59518874
  14. T24CC 000:018.528 OEM: SEGGER
  15. T24CC 000:018.534 Feature(s): GDB, RDI, FlashBP, FlashDL, JFlash, RDDI
  16. T24CC 000:019.405 Bootloader: (Could not read)
  17. T24CC 000:020.152 TELNET listener socket opened on port 19021
  18. T24CC 000:020.284 WEBSRV WEBSRV_Init(): Starting webserver thread(s)
  19. T24CC 000:020.445 WEBSRV Webserver running on local port 19080
  20. T24CC 000:020.535 Looking for J-Link GUI Server exe at: C:\Keil_v5\ARM\Segger\JLinkGUIServer.exe
  21. T24CC 000:020.594 Looking for J-Link GUI Server exe at: C:\Program Files\SEGGER\JLink_V796j\JLinkGUIServer.exe
  22. T24CC 000:020.643 Forking J-Link GUI Server: C:\Program Files\SEGGER\JLink_V796j\JLinkGUIServer.exe
  23. T24CC 000:329.318 Failed to connect to J-Link GUI Server.
  24. T24CC 000:329.645 - 321.052ms returns "O.K."
  25. T24CC 000:329.666 JLINK_GetEmuCaps()
  26. T24CC 000:329.673 - 0.005ms returns 0xB9FF7BBF
  27. T24CC 000:329.680 JLINK_TIF_GetAvailable(...)
  28. T24CC 000:329.982 - 0.303ms
  29. T24CC 000:329.995 JLINK_SetErrorOutHandler(...)
  30. T24CC 000:329.999 - 0.004ms
  31. T24CC 000:330.730 JLINK_ExecCommand("ProjectFile = "D:\Code\Embed\ElectricalValve\AirControlValve\Project\JLinkSettings.ini"", ...).
  32. T24CC 000:366.505 Ref file found at: C:\Keil_v5\ARM\Segger\JLinkDevices.ref
  33. T24CC 000:366.717 REF file references invalid XML file: C:\Program Files\SEGGER\JLink_V796j\JLinkDevices.xml
  34. T24CC 000:367.711 - 36.983ms returns 0x00
  35. T24CC 000:372.390 JLINK_ExecCommand("Device = AC78013MDQA", ...).
  36. T24CC 000:376.422 Device "AC78013MDQA" selected.
  37. T24CC 000:376.746 - 4.335ms returns 0x00
  38. T24CC 000:376.761 JLINK_ExecCommand("DisableConnectionTimeout", ...).
  39. T24CC 000:376.768 ERROR: Unknown command
  40. T24CC 000:376.774 - 0.007ms returns 0x01
  41. T24CC 000:376.779 JLINK_GetHardwareVersion()
  42. T24CC 000:376.784 - 0.004ms returns 95000
  43. T24CC 000:376.788 JLINK_GetDLLVersion()
  44. T24CC 000:376.792 - 0.003ms returns 79610
  45. T24CC 000:376.797 JLINK_GetOEMString(...)
  46. T24CC 000:376.801 JLINK_GetFirmwareString(...)
  47. T24CC 000:376.805 - 0.004ms
  48. T24CC 000:382.794 JLINK_GetDLLVersion()
  49. T24CC 000:382.813 - 0.018ms returns 79610
  50. T24CC 000:382.817 JLINK_GetCompileDateTime()
  51. T24CC 000:382.821 - 0.003ms
  52. T24CC 000:385.084 JLINK_GetFirmwareString(...)
  53. T24CC 000:385.101 - 0.017ms
  54. T24CC 000:387.091 JLINK_GetHardwareVersion()
  55. T24CC 000:387.104 - 0.013ms returns 95000
  56. T24CC 000:388.979 JLINK_GetSN()
  57. T24CC 000:388.990 - 0.010ms returns 59518874
  58. T24CC 000:390.845 JLINK_GetOEMString(...)
  59. T24CC 000:395.073 JLINK_TIF_Select(JLINKARM_TIF_SWD)
  60. T24CC 000:395.573 - 0.500ms returns 0x00
  61. T24CC 000:395.580 JLINK_HasError()
  62. T24CC 000:395.590 JLINK_SetSpeed(5000)
  63. T24CC 000:395.675 - 0.086ms
  64. T24CC 000:395.682 JLINK_GetId()
  65. T24CC 000:397.636 InitTarget() start
  66. T24CC 000:397.647 J-Link Script File: Executing InitTarget()
  67. T24CC 000:501.398 Looking for J-Link GUI Server exe at: C:\Keil_v5\ARM\Segger\JLinkGUIServer.exe
  68. T24CC 000:501.514 Looking for J-Link GUI Server exe at: C:\Program Files\SEGGER\JLink_V796j\JLinkGUIServer.exe
  69. T24CC 000:501.570 Forking J-Link GUI Server: C:\Program Files\SEGGER\JLink_V796j\JLinkGUIServer.exe
  70. T24CC 000:507.612 J-Link GUI Server info: "J-Link GUI server V7.96j "
  71. T24CC 002:374.296 Skipping unsecure.
  72. T24CC 002:381.108
  73. Proceeding without performing the unlock sequence...
  74. T24CC 002:383.452 InitTarget() end - Took 1.98s
  75. T24CC 002:493.490 Failed to attach to CPU. Trying connect under reset.
  76. T24CC 003:103.484 InitTarget() start
  77. T24CC 003:103.522 J-Link Script File: Executing InitTarget()
  78. T24CC 003:110.843 Looking for J-Link GUI Server exe at: C:\Keil_v5\ARM\Segger\JLinkGUIServer.exe
  79. T24CC 003:110.929 Looking for J-Link GUI Server exe at: C:\Program Files\SEGGER\JLink_V796j\JLinkGUIServer.exe
  80. T24CC 003:110.977 Forking J-Link GUI Server: C:\Program Files\SEGGER\JLink_V796j\JLinkGUIServer.exe
  81. T24CC 003:115.993 J-Link GUI Server info: "J-Link GUI server V7.96j "
  82. T24CC 005:513.321 Skipping unsecure.
  83. T24CC 005:516.413
  84. Proceeding without performing the unlock sequence...
  85. T24CC 005:519.022 InitTarget() end - Took 2.41s
  86. T24CC 005:623.930 - 5228.244ms returns 0x00000000
  87. T24CC 006:768.393 JLINK_Close()
  88. T24CC 006:779.037 - 10.642ms
  89. T24CC 006:779.065
  90. T24CC 006:779.069 Closed